| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The devices do not implement any authentication for the web interface or the MQTT server. An attacker who has network access to the device immediately gets administrative access to the devices and can perform arbitrary administrative actions and reconfigure the devices or potentially gain access to sensitive data. |
| The iSTAR door controllers running firmware prior to version 6.6.B, does not support authenticated
communications with ICU, which may allow an attacker to gain unauthorized access |
| Sensitive information disclosure due to missing authentication. The following products are affected: Acronis True Image (macOS) before build 41725, Acronis True Image (Windows) before build 41736, Acronis True Image OEM (macOS) before build 42571, Acronis True Image OEM (Windows) before build 42575. |
| An issue in the Arcadyan Livebox Fibra PRV3399B_B_LT allows a remote or local attacker to modify the GPON link value without authentication, causing an internet service disruption via the /firstconnection.cgi endpoint. |
| Missing Authentication for Critical Function vulnerability in ABB ABB AbilityTM zenon.This issue affects ABB AbilityTM zenon: from 7.50 through 14. |
| A unauthenticated adjacent attacker could potentially disrupt operations by switching between multiple configuration presets via CAN. |
| An unauthenticated adjacent attacker could potentially disrupt operations by switching between multiple configuration presets via Modbus (RS485). |
| A flaw was found in Eclipse Che che-machine-exec. This vulnerability allows unauthenticated remote arbitrary command execution and secret exfiltration (SSH keys, tokens, etc.) from other users' Developer Workspace containers, via an unauthenticated JSON-RPC / websocket API exposed on TCP port 3333. |
| An unauthenticated remote attacker could potentially disrupt operations by switching between multiple configuration presets via Modbus (TCP). |
| Incorrect Implementation of Authentication Algorithm vulnerability in ABB ABB Ability OPTIMAX.This issue affects ABB Ability OPTIMAX: 6.1, 6.2, from 6.3.0 before 6.3.1-251120, from 6.4.0 before 6.4.1-251120. |
| An unauthenticated remote command execution vulnerability exists in Pandora FMS versions up to and including 5.0RC1 via the Anyterm web interface, which listens on TCP port 8023. The anyterm-module endpoint accepts unsanitized user input via the p parameter and directly injects it into a shell command, allowing arbitrary command execution as the pandora user. In certain versions (notably 4.1 and 5.0RC1), the pandora user can elevate privileges to root without a password using a chain involving the artica user account. This account is typically installed without a password and is configured to run sudo without authentication. Therefore, full system compromise is possible without any credentials. |
| A malicious actor can access camera configuration information, including account credentials, without authenticating when accessing a vulnerable URL. |
| An unauthenticated remote attacker could potentially disrupt operations by switching between multiple configuration presets via HTTP. |
| The MinigameCenter module has insufficient restrictions on loading URLs, which may lead to some information leakage. |
| The Archify application contains a local privilege escalation vulnerability due to insufficient client validation in its privileged helper tool, com.oct4pie.archifyhelper, which is exposed via XPC. Archify follows the "factored applications" model, delegating privileged operations—such as arbitrary file deletion and file permission changes—to this helper running as root. However, the helper does not verify the code signature, entitlements, or signing flags of the connecting client. Although macOS provides secure validation mechanisms like auditToken, these are not implemented. As a result, any local process can establish a connection to the helper and invoke privileged functionality, leading to unauthorized execution of actions with root-level privileges. |
| A vulnerability has been identified in SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.4.24), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.4.24), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.4.24). Affected devices do not properly authenticate configuration connections. This could allow an unauthenticated remote attacker to access the configuration data. |
| The SAP Approuter Node.js package version v16.7.1 and before is vulnerable to Authentication bypass. When trading an authorization code an attacker can steal the session of the victim by injecting malicious payload causing High impact on confidentiality and integrity of the application |
| Statistical Database System developed by Gotac has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to read, modify, and delete database contents with high-level privileges. |
| NUP Portal developed by NewType Infortech has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to directly upload files. If the attacker manages to bypass the file extension restrictions, they could upload a webshell and execute it on the server side. |
| Lack of protection against brute force attacks in Valmet DNA visualization in DNA Operate. The possibility to make an arbitrary number of login attempts without any rate limit gives an attacker an increased chance of guessing passwords and then performing switching operations. |