| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Multiple wireless router models from Sapido have an OS Command Injection vulnerability, allowing unauthenticated remote attackers to inject arbitrary OS commands and execute them on the server. The affected models are out of support; replacing the device is recommended. |
| Multiple wireless router models from Sapido have an Exposure of Sensitive Information vulnerability, allowing unauthenticated remote attackers to directly access a system configuration file and obtain plaintext administrator credentials.
The affected models are out of support; replacing the device is recommended. |
| An OS command injection vulnerability exists due to incomplete
validation of user-supplied input. Validation fails to enforce
sufficient formatting rules, which could permit attackers to append
arbitrary data. This could allow an unauthenticated attacker to inject
arbitrary commands. |
| Tigo Energy's Cloud Connect Advanced (CCA) device contains hard-coded credentials that allow unauthorized users to gain administrative access. This vulnerability enables attackers to escalate privileges and take full control of the device, potentially modifying system settings, disrupting solar energy production, and interfering with safety mechanisms. |
| The exos 9300 application can be used to configure Access Managers (e.g. 92xx, 9230 and 9290). The configuration is done in a graphical user interface on the dormakaba exos server. As soon as the save button is clicked in exos 9300, the whole configuration is sent to the selected Access Manager via SOAP. The SOAP request is sent without any prior authentication or authorization by default. Though authentication and authorization can be configured using IPsec for 92xx-K5 devices and mTLS for 92xx-K7 devices, it is not enabled by default and must therefore be activated with additional steps.
This insecure default allows an attacker with network level access to completely control the whole environment. An attacker is for example easily able to conduct the following tasks without prior authentication:
- Re-configure Access Managers (e.g. remove alarming system requirements)
- Freely re-configure the inputs and outputs
- Open all connected doors permanently
- Open all doors for a defined time interval
- Change the admin password
- and many more
Network level access can be gained due to an insufficient network segmentation as well as missing LAN firewalls. Devices with an insecure configuration have been identified to be directly exposed to the internet. |
| Command injection in the <redacted> parameter of a <redacted>.exe request leads to remote code execution as the root user.
This issue affects Iocharger firmware for AC models before version 24120701.
Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). If is a full system compromise, potentially fully compromising confidentiality, integrity and availability of the devicer (VC:H/VI:H/VA:H). A compromised charger can be used to "pivot" onto networks that should otherwise be closed, cause a low confidentiality and interity impact on subsequent systems. (SC:L/SI:L/SA:H). Because this device is an EV charger handing significant amounts of power, we suspect this vulnerability can have a safety impact (S:P). The attack can be automated (AU:Y). |
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root
This issue affects Iocharger firmware for AC model chargers before version 24120701
Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete
files and services. |
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root
This issue affects Iocharger firmware for AC model chargers before version 24120701.
Likelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services.
CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). |
| The WIMP website co-construction management platform from HAMASTAR Technology has a SQL Injection vulnerability, allowing unauthenticated remote attackers to inject arbitrary SQL commands to read, modify, and delete database contents. |
| An unauthenticated remote command execution vulnerability exists in Samsung WLAN AP WEA453e firmware prior to version 5.2.4.T1 via improper input validation in the “Tech Support” diagnostic functionality. The command1 and command2 POST or GET parameters accept arbitrary shell commands that are executed with root privileges on the underlying operating system. An attacker can exploit this by crafting a request that injects shell commands to create output files in writable directories and then access their contents via the download endpoint. This flaw allows complete compromise of the device without authentication. Exploitation evidence was observed by the Shadowserver Foundation on 2025-02-04 UTC. |
| Vulnerabilities* in ActADUR local server product, developed and maintained by ProTNS, allows Remote Code Inclusion on host systems.
* vulnerabilities:
*
Improper Neutralization of Special Elements used in a Command ('Command Injection')
* Use of Hard-coded Credentials
* Improper Authentication
* Binding to an Unrestricted IP Address
The vulnerability has been rated as critical.This issue affects ActADUR: from v2.0.1.9 before v2.0.2.0., hence updating to version v2.0.2.0. or above is required. |
| Official Document Management System developed by 2100 Technology has an Authentication Bypass vulnerability, allowing unauthenticated remote attackers to obtain any user's connection token and use it to log into the system as that user. |
| H3C Intelligent Management Center (IMC) versions up to and including E0632H07 contains a remote command execution vulnerability in the /byod/index.xhtml endpoint. Improper handling of JSF ViewState allows unauthenticated attackers to craft POST requests with forged javax.faces.ViewState parameters, potentially leading to arbitrary command execution. This flaw does not require authentication and may be exploited without session cookies. An affected version range is undefined. Exploitation evidence was first observed by the Shadowserver Foundation on 2024-08-28 UTC. |
| Pro3W CMS if vulnerable to SQL injection attacks. Improper neutralization of input provided into a login form allows an unauthenticated attacker to bypass authentication and gain administrative privileges.
This issue was identified in version 1.2.0 of this software. Due to lack of response from the vendor exact version range could not be determined, but the vulnerability should be eliminated in versions released in January 2026 and later. |
| A remote code execution vulnerability exists in Kaltura versions prior to 11.1.0-2 due to unsafe deserialization of user-controlled data within the keditorservices module. An unauthenticated remote attacker can exploit this issue by sending a specially crafted serialized PHP object in the kdata GET parameter to the redirectWidgetCmd endpoint. Successful exploitation leads to execution of arbitrary PHP code in the context of the web server process. |
| A stack-based buffer overflow exists in the UtilConfigHome.csp endpoint of InterSystems Caché 2009.1. The vulnerability is triggered by sending a specially crafted HTTP GET request containing an oversized argument to the .csp handler. Due to insufficient bounds checking, the input overflows a stack buffer, allowing an attacker to overwrite control structures and execute arbitrary code. It is unknown if this vulnerability was patched and an affected version range remains undefined. |
| LiveBOS, an object-oriented business architecture middleware suite developed by Apex Software Co., Ltd., contains an arbitrary file upload vulnerability in its UploadFile.do;.js.jsp endpoint. This flaw affects the LiveBOS Server component and allows unauthenticated remote attackers to upload crafted files outside the intended directory structure via path traversal in the filename parameter. Successful exploitation may lead to remote code execution on the server, enabling full system compromise. The vulnerability is presumed to affect builds released prior to August 2024 and is said to be remediated in newer versions of the product, though the exact affected range remains undefined. Exploitation evidence was first observed by the Shadowserver Foundation on 2024-08-23 UTC. |
| Quick Agent V3 and Quick Agent V2 contain an issue with improper limitation of a pathname to a restricted directory ('Path Traversal'). If exploited, arbitrary code may be executed by a remote unauthenticated attacker with the Windows system privilege where the product is running. |
| An OS command injection vulnerability exists in various models of E-Series Linksys routers via the /tmUnblock.cgi and /hndUnblock.cgi endpoints over HTTP on port 8080. The CGI scripts improperly process user-supplied input passed to the ttcp_ip parameter without sanitization, allowing unauthenticated attackers to inject shell commands. This vulnerability was reported to be exploited in the wild by the "TheMoon" worm in 2014 to deploy a MIPS ELF payload, enabling arbitrary code execution on the router. Additionally, this vulnerability may affect other Linksys products to include, but not limited to, WAG/WAP/WES/WET/WRT-series router models and Wireless-N access points and routers. Exploitation evidence was observed by the Shadowserver Foundation on 2025-02-06 UTC. |
| The MCP inspector is a developer tool for testing and debugging MCP servers. Versions of MCP Inspector below 0.14.1 are vulnerable to remote code execution due to lack of authentication between the Inspector client and proxy, allowing unauthenticated requests to launch MCP commands over stdio. Users should immediately upgrade to version 0.14.1 or later to address these vulnerabilities. |