| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Heatmiser Netmonitor 3.03 contains a hardcoded credentials vulnerability in the networkSetup.htm page with predictable admin login credentials. Attackers can access the device by using the hard-coded username 'admin' and password 'admin' in the hidden form input fields. |
| Incorrect Implementation of Authentication Algorithm vulnerability in ABB ABB Ability OPTIMAX.This issue affects ABB Ability OPTIMAX: 6.1, 6.2, from 6.3.0 before 6.3.1-251120, from 6.4.0 before 6.4.1-251120. |
| WHILL Model C2 Electric Wheelchairs and Model F Power Chairs do not enforce authentication for Bluetooth connections. An attacker within range can pair with the device and issue movement commands, override speed restrictions, and manipulate configuration profiles without any credentials or user interaction. |
| Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability in rethinkdb.This issue affects rethinkdb: before 2.4.4. |
| The web management interface of Okcat Parking Management Platform from ZONG YU has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to directly access system functions. These functions include opening gates, viewing license plates and parking records, and restarting the system. |
| A vulnerability has been identified in Industrial Edge Device Kit - arm64 V1.17 (All versions), Industrial Edge Device Kit - arm64 V1.18 (All versions), Industrial Edge Device Kit - arm64 V1.19 (All versions), Industrial Edge Device Kit - arm64 V1.20 (All versions < V1.20.2-1), Industrial Edge Device Kit - arm64 V1.21 (All versions < V1.21.1-1), Industrial Edge Device Kit - x86-64 V1.17 (All versions), Industrial Edge Device Kit - x86-64 V1.18 (All versions), Industrial Edge Device Kit - x86-64 V1.19 (All versions), Industrial Edge Device Kit - x86-64 V1.20 (All versions < V1.20.2-1), Industrial Edge Device Kit - x86-64 V1.21 (All versions < V1.21.1-1), Industrial Edge Own Device (IEOD) (All versions < V1.21.1-1-a), Industrial Edge Virtual Device (All versions < V1.21.1-1-a), SCALANCE LPE9413 (6GK5998-3GS01-2AC2) (All versions < V2.1), SIMATIC IPC BX-39A Industrial Edge Device (All versions < V3.0), SIMATIC IPC BX-59A Industrial Edge Device (All versions < V3.0), SIMATIC IPC127E Industrial Edge Device (All versions < V3.0), SIMATIC IPC227E Industrial Edge Device (All versions < V3.0), SIMATIC IPC427E Industrial Edge Device (All versions < V3.0), SIMATIC IPC847E Industrial Edge Device (All versions < V3.0). Affected devices do not properly enforce user authentication on specific API endpoints when identity federation is used. This could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Successful exploitation requires that identity federation is currently or has previously been used and the attacker has learned the identity of a legitimate user. |
| A malicious actor can access camera configuration information, including account credentials, without authenticating when accessing a vulnerable URL. |
| A vulnerability in Longwatch devices allows unauthenticated HTTP GET requests to execute arbitrary code via an exposed endpoint, due to the absence of code signing and execution controls. Exploitation results in SYSTEM-level privileges. |
| New Site Server developed by CyberTutor has a Use of Client-Side Authentication vulnerability, allowing unauthenticated remote attackers to modify the frontend code to gain administrator privileges on the website. |
| EIP Plus developed by Hundred Plus has a Weak Password Recovery Mechanism vulnerability, allowing unauthenticated remote attacker to predict or brute-force the 'forgot password' link, thereby successfully resetting any user's password. |
| An OS command injection vulnerability exists in Vinci Protocol Analyzer that could allow an attacker to escalate privileges and perform code execution on affected system. |
| Legacy Vivotek Device firmware uses default credetials for the root and user login accounts. |
| The Survision LPR Camera system does not enforce password protection by default. This allows access to the configuration wizard immediately without a login prompt or credentials check. |
| Incorrect Permission Assignment for Critical Resource vulnerability in The Wikimedia Foundation Mediawiki - Lockdown Extension allows Privilege Abuse. Fixed in Mediawiki Core Action APIThis issue affects Mediawiki - Lockdown Extension: from master before 1.42. |
| The iSherlock developed by HGiga has an OS Command Injection vulnerability, allowing unauthenticated remote attackers to inject arbitrary OS commands and execute them on the server. |
| The affected Raisecom devices allow SSH sessions to be established without completing user authentication. This could allow attackers to gain shell access without valid credentials. |
| Improper Validation of Integrity Check Value vulnerability in Sharp Display Solutions projectors allows a attacker may create and run unauthorized firmware. |
| Exposure of Sensitive System Information to an Unauthorized Control Sphere vulnerability in Sharp Display Solutions projectors allows a attacker may improperly access the HTTP server and execute arbitrary actions. |
| A flaw in the binding process of Govee’s cloud platform and devices allows a remote attacker to bind an existing, online Govee device to the attacker’s account, resulting in full control of the device and removal of the device from its legitimate owner’s account.
The server‑side API allows device association using a set of identifiers: "device", "sku", "type", and a client‑computed "value", that are not cryptographically bound to a secret originating from the device itself.
The vulnerability has been verified for the Govee H6056 - lamp device in firmware version 1.08.13, but may affect also other Govee cloud‑connected devices. The vendor is investigating other potentially affected models.
The vendor has deployed server-side security enhancements and automatic firmware updates for model H6056. Most of H6056 devices have been successfully patched through automatic updates. Remaining H6056 users with upgradeable hardware versions must manually update firmware through the Govee Home app while keeping their device WiFi-connected. Users should open the Govee Home app, tap their H6056 device card to enter the device details page, tap the settings icon in the upper right corner, navigate to Device Information section (Firmware Version), and tap the Update button to install the security patch immediately.
Govee H6056 devices with hardware versions 1.00.10 or 1.00.11 cannot receive firmware update due to hardware limitations. |
| SQL injection vulnerability based on the melis-cms module of the Melis platform from Melis Technology. This vulnerability allows an attacker to retrieve, create, update, and delete databases through the 'idPage' parameter in the '/melis/MelisCms/PageEdition/getTinyTemplates' endpoint. |