| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An Unverified Password Change could allow a malicious actor with API access to the device to change the system password without knowing the previous password.
Affected Products:
UniFi Connect EV Station (Version 1.1.18 and earlier)
UniFi Connect EV Station Pro (Version 1.1.18 and earlier)
UniFi Connect Display (Version 1.9.324 and earlier)
UniFi Connect Display Cast (Version 1.6.225 and earlier)
Mitigation:
Update UniFi Connect Application to Version 3.10.7 or later.
Update UniFi Connect EV Station to Version 1.2.15 or later.
Update UniFi Connect EV Station Pro to Version 1.2.15 or later.
Update UniFi Connect Display to Version 1.11.348 or later.
Update UniFi Connect Display Cast to Version 1.8.255 or later. |
| Improper handling of OTP/TOTP/HOTP values in NetKnights GmbH privacyIDEA Authenticator v.4.3.0 on Android allows local attackers with root access to bypass two factor authentication. By hooking into app crypto routines and intercepting decryption paths, attacker can recover plaintext secrets, enabling generation of valid one-time passwords, and bypassing authentication for enrolled accounts. |
| Exposed IOCTL with insufficient access control issue exists in cg6kwin2k.sys prior to 2.1.7.0. By sending a specific IOCTL request, a user without the administrator privilege may perform I/O to arbitrary hardware port or physical address, resulting in erasing or altering the firmware. |
| GRAU DATA Blocky before 3.1 stores passwords encrypted rather than hashed. At the login screen, the user's password is compared to the user's decrypted cleartext password. An attacker with Windows admin or debugging rights can therefore steal the user's Blocky password and from there impersonate that local user. |
| Android App "Brother iPrint&Scan" versions 6.13.7 and earlier improperly uses an external cache directory. If exploited, application-specific files may be accessed from other malicious applications. |
| H3C ER8300G2-X is vulnerable to Incorrect Access Control. The password for the router's management system can be accessed via the management system page login interface. |
| YMS VIS Pro is an information system for veterinary and food administration, veterinarians and farm. Due to a combination of improper method for system credentials generation and weak password policy, passwords can be easily guessed and enumerated through brute force attacks. Successful attacks can lead to unauthorised access and execution of operations based on assigned user permissions. This vulnerability affects VIS Pro in versions <= 3.3.0.6. This vulnerability has been mitigated by changes in authentication mechanisms and implementation of additional authentication layer and strong password policies.
|
| HCL DRYiCE Optibot Reset Station is impacted by a missing Strict Transport Security Header. This could allow an attacker to intercept or manipulate data during redirection. |
| Westermo EDW-100 devices through 2024-05-03 allow an unauthenticated user to download a configuration file containing a cleartext password. NOTE: this is a serial-to-Ethernet converter that should not be placed at the edge of the network. |
| The webserver utilizes basic authentication for its user login to the configuration interface. As encryption is disabled on port 80, it enables potential eavesdropping on user traffic, making it possible to intercept their credentials. |
| The product transmits or stores authentication credentials, but it uses an insecure method that is susceptible to unauthorized interception and/or retrieval. (CWE-522)
Hitachi Vantara Pentaho Data Integration & Analytics versions before 10.2.0.0 and 9.3.0.8, including 8.3.x, discloses database passwords when saving connections to RedShift.
Products must not disclose sensitive information without cause. Disclosure of sensitive information can lead to further exploitation. |
| Weak Password Requirements vulnerability in Mitsubishi Electric Corporation photovoltaic system monitor “EcoGuideTAB” PV-DR004J all versions and PV-DR004JA all versions allows an attacker within the Wi-Fi communication range between the units of the product (measurement unit and display unit) to derive the password from the SSID. In addition, if the product is configured to enable the individual air conditioner control function, an attacker who has access to the Wi-Fi communication between the units by exploiting this vulnerability may be able to execute ECHONET Lite commands to perform operations such as turning the air conditioner on or off and changing the set temperature. The individual air conditioner control function is available only in display unit version 02.00.01 or later and measurement unit version 02.03.01 or later. The affected products discontinued in 2015, support ended in 2020. |
| An information disclosure flaw was found in OpenShift's internal image registry operator. The AZURE_CLIENT_SECRET can be exposed through an environment variable defined in the pod definition, but is limited to Azure environments. An attacker controlling an account that has high enough permissions to obtain pod information from the openshift-image-registry namespace could use this obtained client secret to perform actions as the registry operator's Azure service account. |
| Altai Technologies Ltd Altai X500 Indoor 22 802.11ac Wave 2 AP web Management Weak password leakage in the background may lead to unauthorized access, data theft, and network attacks, seriously threatening network security. |
| Insufficiently Protected Credentials vulnerability in Baxter Welch Allyn Configuration Tool may allow Remote Services with Stolen Credentials.This issue affects Welch Allyn Configuration Tool: versions 1.9.4.1 and prior. |
| The standard user uses the run as function to start the MEAC applications with administrative privileges. To ensure that the system can startup on its own, the credentials of the administrator were stored. Consequently, the EPC2 user can execute any command with administrative privileges. This allows a privilege escalation to the administrative level. |
| Extraction of Account Connectivity Credentials (ACCs) from the IT Management Agent secure storage |
| Insufficiently protected credentials in Azure DevOps allows an unauthorized attacker to elevate privileges over a network. |
| A Weak Password Requirements vulnerability in the password management function of Juniper Networks CTP OS might allow an unauthenticated, network-based attacker to exploit weak passwords of local accounts and potentially take full control of the device.
The password management menu enables the administrator to set password complexity requirements, but these settings are not saved. The issue can be verified with the menu option "Show password requirements". Failure to enforce the intended requirements can lead to weak passwords being used, which significantly increases the likelihood that an attacker can guess these and subsequently attain unauthorized access.
This issue affects CTP OS versions 9.2R1 and 9.2R2. |
| Browser caching of LAPS passwords in Truesec’s LAPSWebUI before version 2.4 allows an attacker with access to a workstation to escalate their privileges via disclosure of local admin passwords. |